microHELIX Test Probes your fine-pitch connection

Model 600699 Test Probe

 

 

Model 600699 µHELIX®

Ordering Part Number 600699
Descriptive Model Name S500*3000/650/30@325/B800c4/S0a
material tube & spring (body): 304SS
Plunger: BeCu, Beryllium Copper
i/o end: Insulated copper wire
length body: 3000 µm (0.118 inches)
plunger: 800 µm (0.031 inches)
Length Over All (LOA) 3,80 mm (0.150 inches)
Alternate Lengths in S500 Series
(µHELIX® probes with 20 mill diameter)
 3,05 mm LOA, S500*2440-P1 Group
 3,80 mm LOA, S500*3000-P1 Group
 5,10 mm LOA, S500*3800-P1 Group
 7,10 mm LOA, S500*4500-P2 Group
 8,10 mm LOA, S500*5500-P2 Group
 8,25 mm LOA, S500*6350-P1 Group
 10,15 mm LOA, S500*6350-P2 Group
 10,40 mm LOA, S500*6600-P1 Group
diameter body: 508 µm (0.020 inches)
plunger: 356 µm (0.014 inches)
i/o end: 508 µm (0.020 inches)
i/o wire: 254 µm (0.010 inches)
plunger tip shape: 4-point crown plunger tip
alternate plunger tip shapes sharp, Model 600696
round, Model 600697,
flat, Model 600698
i/o connection: Insulated copper wire, 254 µm diameter i/o end
alternate i/o contact in S500*3000-P1 Group i/o end 600445: annular contact
spring type rectangular helix integral to tube
spring force 30 grams (1.1 oz) at 325  µm (0.013")
alternate force Contact AlphaTest)
spring compliance 650 µm (0.026") maximum
325 µm (0.013 inches) recommended
plating body: 35 µinches Type II Gold
plunger: 35 µinches Type II Gold
For other plating, contact AlphaTest.
lubricant between plunger and probe body none: gold on gold wiping contact
probe resistance < 30 milliohms
μHELIX® spring life > 106 cycles at recommended compliance
installed pointing accuracy drill accuracy ±20 µm (0.0008")
INSTALLATION NOTES:
probe-guide drill size #74; 572 µm (0.0225")
plunger-guide drill size 1/64"; 397 µm (0.0156")
i/o wire clearance hole drill size 1/64"; 397 µm (0.0156")