microHELIX Test Probes your fine-pitch connection

Model 600383 Test Probe

 

 

Model 600383 µHELIX®

Ordering Part Number 600383
Descriptive Model Name S400*3800/900/30@450/B1300c4/B1300c4
material body (tube and coil component): 304SS
plunger: BeCu; Beryllium Copper
pin2: BeCu; Beryllium Copper
length body: 3800 µm (0.150 inches)
plunger: 1300 µm (0.051 inches)
pin2: 1300 µm (0.051 inches)
Length Over All (LOA) 6,40 mm (0.252 inches)
Alternate Lengths  3,30 mm LOA, S400*2300-P1 Group
 3,05 mm LOA, S400*2440-P1 Group
 5,10 mm LOA, S400*3800-P1 Group
 7,10 mm LOA, S400*4500-P2 Group
 8,25 mm LOA, S400*6350-P1 Group
 10,15 mm LOA, S400*6350-P2 Group
diameter body: 406 µm (0.016 inches)
plunger: 320 µm (0.0126 inches)
pin2: 320 µm (0.0126 inches)
plunger tip shape 4-point crownplunger tip
alternate plunger tip shapes sharp, round, flat, 4-point crown
NOTE: Either end can be installed toward the DUT.
pin2 tip shape 4-point crownpin2 end
pin2 alternate tip shapes sharp, round, 4-point crown
NOTE: Either end can be installed toward the DUT.
spring type rectangular helix integral to tube
spring force 30 grams at 450  µm (1.1g@0.018 inches)
alternate force Contact to inquire about alternative probe force.
spring compliance 625 µm (0.025 inches) maximum
450 µm (0.018 inches) recommended
plating body: 35 µinches Type II Gold
plunger: 35 µinches Type II Gold
lubricant between plunger and probe body none: gold on gold wiping contact
probe resistance < 60 milliohms
continous current > 2 Amps
μHELIX® spring life > 106cycles
installed pointing accuracy drill accuracy ±20 µm (0.0008")
INSTALLATION NOTES:
probe-guide drill size #77; 457 µm (0.085 inches)
plunger-guide drill size #80; 343 µm (0.0135 inches)
pin 2 drill size #80 or larger; Fixture designer may opt for more clearance at the i/o board connection