microHELIX Test Probes your fine-pitch connection

Model 600614 Test Probe

 

 

Model 600614 µHELIX®

Ordering Part Number 600614
Descriptive Model Name S500*3800/900/30@450/B1900c4/S-635a
application testing loaded substrate or loaded fine-pitch pcb
This probe has a longer plunger than S500*3800-P1 Group in general
For greater travel (compression) see the S500*4500 and the S500*6350 Groups
material tube & spring (body): 304SS
plunger: hardened BeCu
i/o end: 304SS
length body: 3800 µm (0.150 inches)
plunger: 1900 µm (0.051 inches)
Length Over All (LOA) 5,70 mm (0.224 inches)
Alternate Lengths  3,05 mm LOA, S500*2440-P1 Group
 5,60 mm LOA, S500*3000-P2 Group
 6,40 mm LOA, S500*3800-P2 Group
 7,10 mm LOA, S500*4500-P2 Group
 8,00 mm LOA, S500*5500-P2 Group
 8,25 mm LOA, S500*6350-P1 Group
10,15 mm LOA, S500*6350-P2 Group
diameter body: 508 µm (0.020 inches)
plunger: 356 µm (0.014 inches)
i/o end: 432 µm (0.017 inches)
i/o contact: 275 µm (0.011 inches)
minimum center-center spacing 592 µm (0.023 inches)
plunger tip shape: 4-point crown plunger tip
alternate plunger tip shapes Inquire to AlphaTest
Reference these models:
sharp, Model 600262
round, Model 600263
flat, Model 600264
i/o contact shape: annular ring i/o end
alternate i/o contact Inquire to AlphaTest
spring type rectangular helix integral to tube
spring force 30 grams (1.1 oz) at 450  µm
alternate force Inquire to AlphaTest
Reference Modle 600365 with 100g@350 µm
spring compliance 900 µm (0.035") maximum
450 µm (0.018 inches) typical
plating body: 35 µinches Type II Au over Ni flash
plunger: 35 µinches Type II Au over Ni flash
lubricant between plunger and probe body none: gold on gold wiping contact
probe resistance < 30 milliohms
μHELIX® spring life > 106cycles
installed pointing accuracy drill accuracy ±20 µm (0.0008")
INSTALLATION NOTES:
probe-guide drill size #74; 572 µm (0.0225")
plunger-guide drill size 1/64"; 397 µm (0.0156")
i/o end keeper plate guide hole drill size #76; 508 µm (0.020")