microHELIX Test Probes your fine-pitch connection

Model 600629 Test Probe

 

 

Model 600629 µHELIX®

Ordering Part Number 600629
Descriptive Model Name S500*3800/500/90@350/B1300c4/B1300c4
material tube & spring (body): 304SS
plunger: BeCu
i/o Pin:  BeCu
length body: 3800 µm (0.150 inches)
plunger: 1300 µm (0.051 inches)
i/o Pin:  1300 µm (0.051 inches)
Length Over All (LOA) 6,40 mm (0.252 inches)
alternate lengths  3,05 mm LOA, S500*2440-P1 Group
 5,10 mm LOA, S500*3800-P1 Group
 5,60 mm LOA, S500*3000-P1 Group
 7,10 mm LOA, S500*4500-P2 Group
 8,00 mm LOA, S500*5500-P2 Group
 8,25 mm LOA, S500*6350-P1 Group
10,15 mm LOA, S500*6350-P2 Group
diameter body: 508 µm (0.020 inches)
plunger: 356 µm (0.014 inches)
i/o pin: 356 µm (0.014 inches)
plunger tip shape: 4-point crown plunger tip
alternate plunger tip shapes sharp, 90° cone, Model 600664
i/o probe-end tip shape: 4-point crown i/o end
alternate i/o pin tip shapes sharp, 90° cone, Model 600664
spring type rectangular helix integral to tube
typical spring force 90 grams (3.15 oz) at 350  µm
spring compliance 500 µm (0.020") maximum
350 µm (0.014 inches) typical
plating body: 35 µinches Type II Au over Ni flash
plunger: 35 µinches Type II Au over Ni flash
lubricant between plunger and probe body none: gold on gold wiping contact
probe resistance < 30 milliohms
μHELIX® spring life > 106cycles
installed pointing accuracy drill accuracy ±20 µm (0.0008")
INSTALLATION NOTES:
probe-guide drill size #74; 572 µm (0.0225")
plunger-guide drill size 1/64"; 397 µm (0.0156")
i/o pin-guide drill size =>1/64"; 397 µm (0.0156")

AlphaTest Home faq Products Contact register