microHELIX Test Probes your fine-pitch connection

Model 600766 Test Probe

 

 

Model 600766 µHELIX®

Ordering Part Number 600766
Descriptive Model Name S500*2440/400/30@200/S1300s/S0a
material tube & spring (body): 304SS
Plunger: SS20AP tool steel
i/o end: 304SS
length body: 2440 µm (0.096 inches)
plunger: 1300 µm (0.051 inches)
Length Over All (LOA) 3,74 mm (0.147 inches)
Alternate Lengths in S500 Series
(µHELIX® probes with 20 mill diameter)
3,05 mm LOA, S500*2440-P1 Group
3,74 mm LOA, S500*2440-P1 Group
5,10 mm LOA, S500*3800-P1 Group
6.50 mm LOA, Model 600462
7,10 mm LOA, S500*4500-P2 Group
8,25 mm LOA, S500*6350-P1 Group
10,15 mm LOA, S500*6350-P2 Group
10,40 mm LOA, S500*6600-P1 Group
14,10 mm LOA, S500*9500-P2 Group
diameter body: 508 µm (0.020 inches)
plunger: 356 µm (0.014 inches)
i/o end: 508 µm (0.020 inches)
i/o contact: 275 µm (0.011 inches;)
plunger tip shape: sharp, 90° cone plunger tip
alternate plunger tip shapes for S500*2440-P1 Group Model 600767 with round tip
Model 600768 with flat tip
Model 600769 4-point crown tip
i/o contact: annular ring, 13 µm width i/o end
alternate i/o contact in S500*2440-P1 Group Contact
spring type rectangular helix integral to tube
spring force 30 grams (1.1 oz) at 200  µm
spring compliance 400 µm (0.016 inches) maximum
200 µm (0.008 inches) recommended
plating body: 35 µinches Type II Gold
plunger: 35 µinches Type II Gold
For other plating, contact AlphaTest.
lubricant between plunger and probe body none: gold on gold wiping contact
probe resistance < 30 milliohms
μHELIX® spring life > 106cycles at recommended compliance
installed pointing accuracy drill accuracy ±20 µm (0.0008")
INSTALLATION NOTES:
probe-guide drill size #74; 572 µm (0.0225")
plunger-guide drill size 1/64"; 397 µm (0.0156")
Recommended i/o end contact pad =>254µm (0.010") Gold plated.
(Minimum pad size 126µm (0.005"))

AlphaTest Home faq Products Contact register